The analyzer that physicians trust with robust technology highlighted in more than 140 clinical articles, dca systems are used by three out of four physicians who perform hba1c testing in the office. Siemens dca vantage wilburn medical usa 18779452876. Quick reference guide instrument setup is performed daily before patient testing. Dca vantage analyzer and accessories by siemens healthcare analyzer lets you monitor glycemic control and detect early kidney disease with fast, actionable test results that can help you assess the effectiveness of a treatment plan and make adjustments. It is a semiautomated, benchtop analyzer designed to quantitatively measure the percent hemoglobin al c hbal c in blood and low concentrations of albumin in urine.
Examining hemoglobin a1c testing methods for accuracy, diabetes controls guarantee quality patient level readings. Operators manual siemens dca vantage operators manual 214 pages. Samples analyzed by the dca 2000, a siemens floormodel product with similar immunoassay components to the dca vantage, are falsely elevated when hbf is 10% and result in a clinically significant impact on patient care when it is 20%. It is a semiautomated, benchtop analyzer designed to quantitatively measure the percent hemoglobin al c hbal c in. The dca vantage analyzer helps you monitor glycemic control and detect early kidney disease in environments ranging from the physicians. Jan 24, 2017 siemens dca vantage analyzer buy it here. The dca vantage analyzer is a pointofcare analyzer for diabetes management. Fast, actionable test results at the point of care can help you determine the effectiveness of a treatment plan, make therapeutic adjustments with greater confidence, and be certain that patients are complying with your. Dca vantage analyzer and accessories by siemens healthcare. Assessment of two diabetes pointofcare analyzers measuring. Dca vantage analyzer helps you manage diabetes patients by providing quick results to enable actionable physicianpatient conversations at the time of the visit. Siemens dca vantage stattechnologies provide the clinical confidence your patients deserve. Dca vantage hba1c analyzer, clia waived 10282969 for sales in us only drop ship only.
For detailed procedural information about performing a calibration, refer to the dca vantage operators guide. The dca vantage system supports a serial connection or an ethernet connection between instrument and host. Download forms and certificates, inservice training tools, and product documentation for the clinitek advantus urine chemistry analyzer, clinitek status family of analyzers, dca vantage analyzer, urinalysis test strips and xprecia stride coagulation analyzer. Dca vantage analyzer helps you better manage diabetes patients by providing. Dca vantage analyzer user manual archive of dca vantage analyzer user manual is a fast, easytouse dca vantage analyzer user manual that is perfect for sorting through large volumes of articles and headlines. Analyzer with onboard printer, power supply cable, operating manual, cleaning kit and optical test cartridge. Performing hemoglobin a1c quality control video pepconnect. If the capillary holder is missing any of the above parts, discard the capillary holder. After comparing against the patient blood samples, the obtained percentages will indicate. The dca vantage analyzer siemens medical solutions diagnostics, tarrytown, ny, usa uses an immunoassay based on antibodies binding to glycated hemoglobin tetrapeptide or hexapeptide molecules using a 1.
The dca vantage analyzer is the diabetes system that delivers clinically proven, clinically relevant hba1c and a. The dca vantage analyzer helps you monitor glycemic control and detect early kidney disease in environments ranging from the physicians office to remote, pointofcare coordinated sites in hospitals and multisite practices. Quantitative measurement of hemoglobin a1c on the dca. Call or contact us for pricing and availability 369966820 or 1877wilburn 18779452876. Siemens 5075us dca vantage analyzer wilburn medical usa. The dca vantage tm analyser is a semiautomated, bench top system. Siemens dca vantage analyzer medical healthcare hemoglobin analyzers lab equip. View and download siemens dca vantage operators manual online. The dca vantage system is cliawaived only when used with siemens branded dca. The cause for the discordant hemoglobin hba1c results in. C ratio results shown to improve patient compliance. Hba1c test cartridge is at room temperature for a minimum of 10 minutes before use. The serial interface is compatible with the eia232d specification.
We have 1 siemens dca vantage manual available for free pdf download. Hba1c test cartridge is used within 1 hour if removed from the foil package. The dca vantage analyzer provides you with inhouse albumin, creatinine, and a. Selecting an a1c pointofcare instrument diabetes spectrum. Ethernet connections using astm dca vantage analyzer host computer communications link manual. Dca vantage analyzer for diabetes control, siemens healthineers. Dca vantage analysesystem siemens healthineers deutschland. Siemens healthineers and hillrom to provide comprehensive. Automatically upload results and qc information to lishis to reduce manual. Siemens healthineers dca vantage analyzer dca vantage.
Continuous gas analysis gas analyzer for measuring irabsorbing gases, oxygen and. Siemens dca vantage analyser for hba1c effective date. Dca vantage analyzer from siemens healthineers selectscience. Siemens representative ran 10 consecutive normal and 10 abnormal controls on the instrument. The dca vantage analyzer from siemens healthcare diagnostics is a pointof care device that quantitatively measures percent hba1c in blood. Provide the clinical confidence your patients deserve. Control kits hba1c normalabnormal control combination kit. Meet labquality testing standards with an analyzer that speeds and simplifies diabetes tests and delivers accurate. Evaluation of the dca vantage analyzer for hba1c assay. Our dca tm hba1c and dca microalbumin creatinine tests are clinically proven1,2,3,4 and the most widely used5 brands. C ratio testing with labquality sensitivity and specificity. The human blood based substances are used in diagnosing the condition in addition to routine glucose averages. Simple enough to use in your office lab, and yet powerful enough to deliver labquality performance in. This internal validation study assessed the precision, agreement, and bias of the dca hba1c test against an ngspcertified laboratory hplc method.
The procedure provides instructions for hba1c quality control testing with the dca vantage. The method uses a monoclonal antibody raised against a specific glycated amino acid sequence of hba1c. The dca vantage analyzer from siemens healthcare diagnostics is a pointofcare device that quantitatively measures percent hba1c in blood. It is designed to quantitatively measure the percent of haemoglobin a1c in blood and low concentrations of albumin in urine microalbuminuria, creatinine in urine, and the albumincreatinine ratio in urine. Siemens healthineers dca vantage analyzer provides precise and accurate quantitative test results for hba1c in whole blood during the patient visit to help improve decision making manufacturer. Our hba1c and microalbumin products are clinically proven and trusted worldwide. Poct analyzer methods the dca vantage system siemens medical solutions diagnostics, tarrytown, new york 105915097, usa is based on a heterogeneous immunoassay using latex agglutination. Siemens diagnostics dca vantage hba1c analyzer, clia waived 10282969 for sales in us only drop ship only base price.
Its simple enough to use in your office lab, and yet powerful enough to deliver labquality performance in pointofcare coordinated. Dca vantage instrumente diabetes humanmedizin praxis. The cause for the discordant hemoglobin hba1c results in unknown. The dca vantage analyzer provides labaccurate results for monitoring glycemic control in patients with diabetes and conducting regular checks for kidney disease.